01

Define the unit before counting it

A probe is one attempt under stated conditions. Before calculating anything, the monitor must define the request, timeout, retry policy and observation node. Without those fields, two samples may not be comparable enough to share a denominator.

Retries need special care. If each timeout triggers several immediate attempts, counting all attempts can overweight a brief network problem. Counting only the final outcome hides the retry policy. Either approach can work if it is explicit and consistent.

02

The percentage belongs to a window

Ninety-nine percent availability for a day, a month and a year describe different histories. The label must identify the start, end and expected sample interval. A window with five checks cannot support the same practical confidence as one with thousands.

A new project should show the number of published samples beside any ratio. This prevents a small initial series from appearing as mature as a long operational history.

03

Missing samples are not successful samples

A monitor can fail while the observed service remains healthy. Excluding those intervals without disclosure biases the result, while treating them as service downtime creates a different error. The clean approach is to identify monitor gaps separately.

Scheduled maintenance of the observation system belongs in the same record. Readers can then distinguish a service event from a period in which no valid measurement exists.

04

Publish the series behind the summary

An aggregate is easier to audit when the underlying timestamped outcomes remain available. Rounding can simplify display, but it should not erase failures, unknown states or method changes.

DarkObservatory starts with no historical uptime ratio. Real observations must accumulate first. This is slower than importing an attractive number, but it keeps the resulting history meaningful.

FIELD PROTOCOL

Minimum fields for an uptime statement

  1. 01Start and end of the observation window.
  2. 02Expected interval and actual sample count.
  3. 03Request, node, timeout and retry definitions.
  4. 04Separate treatment of monitor gaps and inconclusive results.
  5. 05Access to the underlying observations or a reproducible summary.

FAQ / EVIDENCE

Common questions

Can ten successful probes justify 100% uptime?+

Only for that narrowly defined sample, and even then the small sample and missing intervals must be visible. It does not establish a broad historical rate.

Should monitor maintenance count as service downtime?+

No. It is a measurement gap unless independent service evidence exists.

Why avoid an uptime number at launch?+

Because no meaningful historical series exists yet. A number without samples would be cosmetic rather than informative.

Evidence and further reading

  1. Tor Metrics↗

    Examples of network measurement context and historical series; not individual market data.

  2. NIST: uncertainty of measurement↗

    General background for transparent measurement limits.

BOUNDARY / 01

A network observation describes one node at one time. It is not a safety judgement or transaction test.